Plate Thickness and Web Height Shape Built-Up Cold-Formed Steel Beam
A comprehensive finite element investigation into built-up cold-formed steel beams has demonstrated that increasing plate thickness from 1 millimeter to 3 millimeters boosts ultimate bending resistance by more than 300 percent. The study, conducted by research
Illustrative imageA comprehensive finite element investigation into built-up cold-formed steel beams has demonstrated that increasing plate thickness from 1 millimeter to 3 millimeters boosts ultimate bending resistance by more than 300 percent. The study, conducted by researchers Qiang Xu and Jianyong Song, modeled both open back-to-back and closed face-to-face configurations using nonlinear numerical techniques in ABAQUS. Cold-formed steel members offer favorable strength-to-weight ratios, economical fabrication, and structural flexibility in modern construction. However, their thin-walled geometry creates high width-to-thickness ratios that render them susceptible to local, distortional, and lateral-torsional buckling under flexural loading. To address these vulnerabilities, engineers frequently assemble individual channels into built-up configurations with stiffened hollow flanges. Xu and Song established a controlled computational program to isolate how primary cross-sectional parameters—specifically plate thickness, web depth, flange width, and sectional arrangement—interact to govern moment capacity and buckling failure mechanisms.
The finite element modeling strategy implemented by the research team employed four-node reduced integration shell elements, known as S4R, within the Abaqus/CAE environment to capture localized and distortional deformations across the thin-walled plates. Taking advantage of geometric and loading symmetry, the team modeled an 800-millimeter half-span beam subjected to displacement-controlled four-point bending, representing a full span of 1600 millimeters. A structured mesh was generated along the member length and cross section, utilizing nominal element sizes of approximately 5 by 5 millimeters for sections with an 86-millimeter web height and 10 by 10 millimeters for deeper sections. A mesh convergence study conducted on an 86-millimeter web validation specimen revealed that refining element dimensions from 5.0 millimeters to 3.75 millimeters altered peak moment predictions by only 0.268 percent and curvature by 0.36 percent, while maintaining a normalized root-mean-square error of 1.36 percent. Consequently, the 5-millimeter mesh was selected to balance numerical accuracy and computational economy.
Material behavior in the simulations was captured using a nonlinear elastic-plastic constitutive model calibrated against experimental tension coupon tests, featuring an elastic modulus, measured yield strength, ultimate tensile strength, fracture strain, and a Poisson’s ratio of 0.3. Initial geometric imperfections were systematically introduced through prior linear eigenvalue buckling analyses executed as perturbation steps with geometric nonlinearity disabled. The displacement field of the lowest relevant local buckling mode was applied to each model, scaling the peak amplitude to 0.5 times the base plate thickness. Fastener connections joining individual channels were modeled using tie constraints positioned at prescribed screw locations, enforcing displacement continuity without modeling localized screw slip, fastener shear deformation, or pull-out failure. Overlapping plate contacts were simulated using surface-to-surface definitions incorporating hard normal contact to prevent interpenetration and frictionless small-sliding tangential interactions.
The numerical framework was validated against experimental four-point bending data from published studies, initially comparing predictions against three cold-formed steel specimens tested by Wang and Young. For the closed-section specimen CT1.9-86-S300, the numerical simulation slightly underestimated ultimate moment capacity by 9.28 percent, while open-section specimens OT1.2-86-S300 and OT1.2-136-S150 yielded signed percentage errors of negative 0.24 percent and positive 7.16 percent, respectively. Across these three reference beams, absolute percentage errors spanned from 0.24 to 9.28 percent, achieving a mean absolute percentage error of 5.56 percent and an average predicted-to-experimental capacity ratio of 0.992. Numerical failure modes closely matched experimental records, predicting pure local buckling in the closed channel and combined distortional and local buckling in the open sections. Additional verification using an unheated experimental specimen from Kumar and colleagues demonstrated strong tracking of pre-peak load-deflection behavior, predicting a peak load of 299.2 kilonewtons compared to the measured 297.4 kilonewtons, reflecting a difference of just 0.61 percent.
Following successful validation, the authors conducted a parametric evaluation comprising a discrete matrix of 30 finite element models to quantify how geometric proportions alter structural performance. The matrix explored two built-up sectional profiles: a closed face-to-face arrangement and an open back-to-back arrangement. Plate thicknesses were evaluated at 1, 2, and 3 millimeters across two web heights of 130 millimeters and 155 millimeters. For the 130-millimeter web group, flange widths of 40, 50, and 60 millimeters were paired with a dependent central vertical web dimension fixed at 20 millimeters. For the 155-millimeter web series, flange widths of 50 and 60 millimeters were examined with a central web dimension fixed at 45 millimeters. All models maintained an edge-lip length of 20 millimeters and an inclined web-transition segment of 18.03 millimeters, preserving consistent boundary conditions, displacement rates, contact definitions, and nonlinear stabilization parameters across the entire comparative suite.
Among all geometric variables investigated, plate thickness exerted the most dominant influence on structural capacity across both section configurations. For beams with a 130-millimeter web height, increasing plate thickness from 1 millimeter to 3 millimeters raised the average ultimate moment of closed sections from approximately 9,700 to 41,000 kilonewton-millimeters, and open sections from approximately 9,900 to 41,000 kilonewton-millimeters. In the 155-millimeter web series, increasing thickness from 1 to 3 millimeters elevated closed-section mean capacity from 12,400 to 54,600 kilonewton-millimeters, while open-section capacity climbed from 13,100 to 50,800 kilonewton-millimeters. This capacity expansion of more than 300 percent significantly outpaced the linear addition of steel material area. Thicker plates substantially reduced width-to-thickness slenderness ratios across the web and flange elements, delaying the onset of local instabilities and enabling larger cross-sectional regions to remain structurally effective under elevated bending stresses.
Web height adjustments also provided substantial capacity enhancements by extending the internal lever arm between compression and tension zones. Deepening the web from 130 millimeters to 155 millimeters generated flexural capacity improvements between 15 and 29 percent across the design matrix. In closed configurations with 60-millimeter flanges, increasing web depth resulted in consistent gains of approximately 29.1, 27.9, and 28.4 percent for thicknesses of 1, 2, and 3 millimeters, respectively. For open sections, web deepening generated capacity improvements of 20 to 27 percent at thicknesses of 1 and 2 millimeters, dropping to 15 to 17 percent at a thickness of 3 millimeters. While deeper webs heightened the gross section modulus, they also increased web slenderness ratios. Closed sections utilized this added height more efficiently due to their inherent torsional rigidity, whereas open configurations experienced greater sensitivity to torsional warping and web plate distortion.
Modifications to flange width revealed distinct behavioral differences between the two structural arrangements, with open configurations exhibiting greater sensitivity to flange dimensioning. For closed sections with a 130-millimeter web, expanding flange width from 50 to 60 millimeters produced modest capacity improvements of approximately 7 percent at thicknesses of 2 and 3 millimeters, and similar 7 percent gains for 155-millimeter webs at 3 millimeters thickness. In contrast, expanding the flange width of open sections from 50 to 60 millimeters in 130-millimeter webs yielded capacity increases of 25 percent at 1 millimeter thickness and 28 percent at 3 millimeters thickness. Because open configurations possess lower baseline torsional and rotational stiffness, widening the stiffened hollow flange significantly stiffens the compression flange assembly against distortional deformation. In closed beams, where torsional restraint is already substantial, widening flanges delivered smaller marginal capacity increments.
Direct comparisons between paired open and closed profiles showed that neither cross-sectional shape maintained consistent superiority across all dimensions, with the open-to-closed capacity ratio ranging from 0.862 to 1.097 across the 15 paired configurations. Open arrangements provided superior flexural capacity in 10 comparisons, primarily at thinner plate gauges of 1 and 2 millimeters where their sectional distribution delivered a 1 to 7 percent capacity advantage. Conversely, closed configurations proved superior in the remaining 5 comparisons, all concentrated in 3-millimeter-thick sections where they surpassed open counterparts by 7 to 10 percent. At thinner dimensions, high plate slenderness triggers early localized buckling that restricts the closed section from mobilizing its superior torsional stiffness. When plate thickness reaches 3 millimeters, suppressed local buckling allows closed sections to exploit their closed-loop torsional resistance and prevent channel twisting under peak loading.
Normalized curvature analyses demonstrated that post-peak moment retention remained highly stable across configurations, with the post-peak retention index at 1.25 times peak curvature averaging 0.948 for closed beams and 0.937 for open beams. Peak failure assessments across representative models indicated that maximum equivalent plastic strains ranged from 0.0061 to 0.0538, while out-of-plane web displacements reached 2.062 to 3.939 millimeters. Across all 30 models, the maximum ultimate moment of 56,495.865 kilonewton-millimeters was attained by the closed model C3-h155-b60, whereas the lowest capacity of 8,545.380 kilonewton-millimeters occurred in the open beam O1-h130-b40. While the findings provide practical guidance for sizing built-up cold-formed steel beams, the authors noted that the analysis was restricted to 1600-millimeter spans under idealized screw connections without thermal degradation or dynamic effects, highlighting the necessity of future experimental testing across broader geometric and connection domains.
Subject of Research: Flexural capacity and buckling mechanics of open and closed built-up cold-formed steel beams
Article Title: Flexural capacity and failure characteristics of built-up cold-formed steel beams
Article References: Xu, Q., & Song, J. (2026). Flexural capacity and failure characteristics of built-up cold-formed steel beams. Journal of Engineering and Applied Science, 73(1), Article 472. https://doi.org/10.1186/s44147-026-01301-2
Image Credits: AI Generated
DOI: 10.1186/s44147-026-01301-2
Keywords: cold-formed steel, built-up beams, flexural capacity, finite element analysis, local buckling, distortional buckling, lateral-torsional buckling, ABAQUS, structural engineering, elastic section modulus, closed section, open section, moment-curvature response, plate thickness, web height, slenderness ratio, four-point bending
News Source: Denise Maddox. (November 23, 2026). Plate Thickness and Web Height Shape Built-Up Cold-Formed Steel Beam Capacity. Scienmag.